CCZWL - 202 EZ 1 PVC CEMENT
- MSDS: CCZWL
- Manufacturer: PCI INDUSTRIES INC
- Product Name: 202 EZ 1 PVC CEMENT
- National Stock Number: 8030-00F052043
Product Identification
Product ID:202 EZ 1 PVC CEMENT
MSDS Date:02/07/1995
FSC:8030
NIIN:00F052043
MSDS Number: CCZWL
Responsible Party
RIVIERA BEACH, FL 33149-5000
US
Emergency Phone: 407-844-0241
Info Phone: 407-844-0241
Preparer: N JOHNSON
Cage: FO174
Contractor
Telephone: (407) 844-0241
Cage: FO174
Ingredients
TETRAHYDROFURAN
CAS: 109-99-9
RTECS: LU5950000
Fraction By Weight: <50%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYL ETHYL KETONE, 2-BUTANONE *96-3*
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: <50%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETONE; DIMETHYL KETONE; 2-PROPANONE *96-3*
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: <50%
OSHA PEL 750 PPM
ACGIH TLV: 750 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
CHLOROETHYLENE POLYMER, POLYVINYL CHLORIDE
CAS: 9002-86-2
RTECS: KV0350000
Fraction By Weight: <50%
Hazards
LD50 LC50 Mixture:ORAL LD50(RAT): 2816 MG/KG (SEE SUPP)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: CAUSES RESPIRATORY
IRRITATION. SKIN: IRRITATION. LOCAL & SYSTEMIC EFFECTS DUE TO
REPEATED/LONG TERM EXPOSURE TO THE EYES, SKIN/THROUGH INHALATION &
INGESTION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, HEADACHE, REDNESS, TEARING, BLURRED
VISION, DEFATTING, DRYNESS, RASH, NAUSEA, VOMITING, DIZZINESS,
STUPOR, DIARRHEA.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS.
First Aid
First Aid:EYES: FLUSH W/PLENTY OF WATER FOR 15 MINS. INGESTION: IF
CONSCIOUS, DILUTE BY GIVING 2 GLASSES OF WATER. KEEP WARM & QUIET.
DON'T INDUCE VOMITING. SKIN: FLUSH W/WATER. INHALATION: REMOVE TO
FRESH AIR. GIVE CPR IF NEEDED. OBTAIN MEDICAL ATTENTION IN ALL
CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:6F
Lower Limits:1.8
Upper Limits:13.2
Extinguishing Media:FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA W/FULL FACEPIECE OPERATED IN
PRESSURE DEMAN/OTHER POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:VAPORS ARE > THAN AIR & TRAVEL ALONG THE
GROUND & IGNITE AT DISTANT LOCATION MATERIAL TO HANDLING POINT.
Accidental Release
Spill Release Procedures:EXTINGUISH & DON'T TURN ON ANY IGNITION SOURCE
UNTIL AREA IS DETERMINED TO BE FREE OF EXPLOSION/FIRE HAZARDS.
ABSORB W/SAND/INERT MATERIAL. DISPOSE OF AS SOLID WASTE.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & FLAME.
USE W/ADEQUATE VENTILATION. KEEP CONTAINER CLOSED.
Other Precautions:AVOID BREATHING VAPORS & CONTACT W/EYES, SKIN &
CLOTHING. CONTAINERS OF THIS MATERIAL MAY BE HAZARDOUS WHEN EMPTY
SINCE EMPTIED CONTAINERS RETAIN RESIDUES, VAPOR, LIQUID &/SOLID.
ALL HAZARD PRECAUTION S MUST BE OBSERVED.
Exposure Controls
Respiratory Protection:THE TLV IS EXCEEDED, A NIOSH/MSHA APPROVED AIR
SUPPLIED RESPIRATOR IS ADVISED. OSHA PERMITS OTHER NIOSH/MSHA
RESPIRATORS UNDER SPECIFIED CONDITIONS.
Ventilation:IN A CONFINED AREA: MECHANICAL (GENERAL &/LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLVS. USE EXPLOSION PROOF EQUIPMENT.
Protective Gloves:LINER/BUTYL/OTHER IMPERVIOUS
Eye Protection:CHEMICAL SAFETY SPLASH GLASSES
Other Protective Equipment:FACESHIELD, BATH, SAFETY SHOWER, RUBBER
SAFETY BOOTS.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER USING.
Supplemental Safety and Health
THE ORAL LD50 INFORMATION IS FOR TETRAHYDROFURAN.
Chemical Properties
Boiling Pt:B.P. Text:133-175F
Vapor Density:>1
Spec Gravity:0.9
Evaporation Rate & Reference:FASTER THAN N-BU AC
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR LIQUID W/STRONG SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME & OTHER SOURCES
OF IGNITION.
Hazardous Decomposition Products:CO2, CO & VARIOUS HYDROCARBONS.
Disposal
Waste Disposal Methods:INCINERATE/DISPOSE OF IF PERMITTED & ALLOW TO
EVAPORATE/SOLIDIFIED W/INERT MATERIAL IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.